Compact with external temperature sensor, a memory capacity of 4000 records. Wireless configuration and data acquisition through its NFC interface (Near Field Communication) by using android smartphones or tablets. Internal battery life of 400 days (not replaceable).
Features:
- Measure range: -40 °C to +70 °C
- Temperature Accuracy: ±0.5 °C to 25 °C; ±1.0 °C on all range
- Measurement resolutions: 0.1 °C
- Memory capacity: 4.020 logs
- Measurement interval: Programmable between 5 min and 2 h
- Configuration and Acquisition: RFID ISO 15693 (NFC-V)
- Free Android App LogChart-NFC available for Android 4.0 and higher smartphones with NFC interface
- Optional USB to NFC computer interface allows communication using LogChart-II software on Windows operating system
- Power: Lithium Battery, 3 V, internal, not replaceable
- Battery Autonomy: 400 days with 15 min acquisition break
- Housing: Polyamide body injected. Protection length IP67
- Dimensions: 65 x 44 x 8 mm (temperature sensor not included)